Supply of high pressure in set cabinet KYN28A-12,, (GZS1) cabinet professional production, the industry leader.
Information Name: | Supply of high pressure in set cabinet KYN28A-12,, (GZS1) cabinet professional production, the industry leader. |
Published: | 2012-03-21 |
Validity: | 360 |
Specifications: | KYN28A-12 |
Quantity: | 888.00 |
Price Description: | |
Detailed Product Description: | Outline KYN28-12 (Z) armored remove the AC metal-enclosed switchgear (hereinafter referred to as switchgear) for three-phase AC 50Hz, 3.6 ~ 12kV single busbar system in sub-sets of power distribution equipment, as the acceptance and distribution networks of electricity, and circuit implementation of the control, protection and monitoring of a wide range in electric power, metallurgy, petrochemical, urban construction and other industries. This switch cabinet to meet the IEC298 GB3906, DL/T404, standard requirements, and has the perfect "anti-feature. This switch cabinet can be configured to the VD4, 3AH, EV12, of VB2 VS1 (ZN63A,) VDS (ZN63C),, ZN18 (VK) and other circuit breaker. Models and their meanings Environmental conditions Ambient temperature: the maximum temperature of +40 ° C, minimum temperature -10 ℃. Ambient humidity: daily average relative temperature ≤ 95%, the average monthly relative humidity: 90%. Earthquake intensity: seismic intensity of more than 8 degrees. Altitude: 1000m. Ambient air should not corrosive or combustible gases, water vapor and other obvious pollution. No frequent violent vibration place. Consultation by the users and manufacturers use more than the the GB3906 prescribed normal environmental conditions. Structure outlined Switchgear of this model is in accordance with the provisions in the GB3906-91 armored away design, manufacture. Level of protection of the shell for IP4X; level of protection for each compartment IP2X. Switchgear components (referred to as car) away from the cabinet and can be composed of two parts. Cabinet This type of switchgear cabinet assembly structure, the main component is aluminum-zinc steel plate, made by CNC machining. Multiple bending process and pull the rivet nuts, high strength bolts, the switchgear to ensure sufficient strength and rigidity at the same time, lighter, stronger to resist the ability of the harmful gas corrosion, and look more beautiful. The cabinet structure in accordance with the cabinet of the main functional elements separated for the car room, main busbar room, cable room (current transformer room) and the relay room (see Figure 2). In addition to the relay room, and the remaining compartment set accident exhaust channel leading to the top of the cupboard. The bottom of the car room, a car track for the movement of the car in the cabinet. Compartment installed in the main circuit of the static contact contact box and the main bus compartment and cable compartment connected. When the car in the test location or exit outside the cabinet, the activities of the curtain plate static contact cover to form an effective isolation; activities curtain panels open automatically, when the car move from the test position to working position, to ensure the smooth connection of the main circuit. Activities under the curtain board independence movement, and can be locked. Therefore, if necessary, maintenance personnel can lock the live side of the curtain plate, overhaul the other side of the main loop static contact. The main bus indoor installation of a three-phase rectangular copper bus. The main bus of the switchgear room by tube connected to the main busbar room cabinet in the run-time is separated to avoid an interval unexpected to hurt other switchgear scalability accident occurred. Cable indoor according to the needs of the main loop program, you can install the current transformers, grounding switch, charged the display device and a fixed main cable architecture, accessories. The switch cabinet on the floor to open the main cable into the hole and removable closure plate. Each phase of the switchgear and connected to the root of l-3 single-core cable. The relay room is used to install the protection, control, and the secondary component. The left side of the small room equipped for the control cable out of the trough: in a small room at the top has a small bus through the hole, the wiring when the top cover can be rotated to facilitate the installation of a small bus. Need to observe the instrument device can be installed on the door of relay room, regular operation of the switch and embedded relay. Car According to the different components of the main circuit configuration of a small car, car circuit breakers, voltage transformers car, isolating car and measurement car. All kinds of car building block changes in modulus with the specifications of the car to ensure interchangeable. Car location and the location of the test (disconnect) two targeted locations in the cabinet. The advancement of the car (exit) using a worm gear and effort institutions, lightweight, and flexible. Car out of the cabinet outside, you need to configure the dedicated transshipment trolley. The car transporter car brought into cabinet, first locate the location of the test (disconnect), the car with the cabinet is locked, you can shake the advance mechanism will push the car to a working position. Car to reach the working position, shake shake blocked the car in place. Car interlocking institutions to ensure that only the circuit breaker in the state of the sub-gate, the car can not be moved, the only car in the positioning of the test (disconnect) position or work location, the circuit breaker before closing. Interlock ● This type of switchgear design a reliable "five anti-locking system. A. Circuit breaker to prevent accidental cooperation, sub-operation, we recommended the adoption of the breaker control switch with red, green flop to achieve. Users accustomed to using other anti-misuse measures may be made when ordering. B. The switch cabinet latch to ensure that the breaker car in the test or working position, the circuit breaker can be carried out together, sub-operation, the circuit breaker closing, the car will not be able to exercise. Prevent the loading pulling the car. C. The switch cabinet latch guarantee only if the earthing switch in the OFF position, the car from the test position to move to the working position; only when the car in the test position, the earthing switch closing operation. In addition, the grounding switch is necessary, you can configure the live display device. Therefore, the charged closing earthing switch and earthing switch can prevent the misuse occurred in the transmission of the closing state. D. The switch cabinet latch to ensure that the grounding switch is not closing, the next door and cabinet back door can not open the cabinet before. In order to prevent mistakenly charged interval. ● Vice secondary plug and car position interlock. The secondary of the switchgear cabinet and trolley lines connected through the second plug. Secondary plug is connected by a corrugated extension tube and trolley; the second outlet installed in the top right of the cabinet trolley room. The only car in the test position, you can plug in or unplug the secondary plug. The car in working position, the interlock secondary plug is locked so that it can not be pulled. If the secondary power supply is not connected to the circuit breaker closing institutions can be electromagnetic locks. Installation and adjustment ● cabinet a separate cabinet front porch to 2.5 meters is appropriate, two-column layout, cabinet operating corridor 3 meters is appropriate. ● switchgear engineering drawings will switchgear transported to the predetermined position, more than 10 row from the middle of the beginning. ● switchgear should be used during transport, transport tools, such as a crane or forklift is prohibited to use the roller, skid bars, and is strictly prohibited with the handling of the car pushed into the cabinet, the withdrawable only after the cabinet is installed again and again into the corresponding cabinet. ● Loosen the top of the busbar pressure relief cover bolts, remove the cover. ● Remove the cable seal plate. ● Remove the cover of the second line groove. ● Remove the lifting plate and fasteners. ● Based on the above, one by one to install switchgear installation roughness shall not exceed 2mm. ● available bolt switchgear combination assembled its underlying components associated or welding or building blocks weld. Bus installation The KYN mouth set cabinets bus piecewise rectangular bus bar, the installation must follow these steps: ● clean dry soft cloth bus Wipe clean and check the heat-shrinkable tube or curing the coating surface defects in the joints coated with a conductive paste or neutral Vaseline. ● install a cabinet to the bus, the bus and the corresponding branch bus connected together into a suitable pad should be bolted with bolts tightened. Counters in the home ground of the installation. ● cabinet grounding bus together. ● to connect all the grounding of the lead in the cabinet. ● the basic components and the ground connection, more than 10 units or more must have two or more of the grounding wire. Cable installation ● production of cable head cable construction specification and with the cabinet terminal connections. Cable clamps to secure the cable at cable closure panel and tighten the cable seal plate. Inspection after the end of the installation of the switchgear ● When the switch cabinet in place, remove the drawer of dust, debris, and then check the sturdy loose bolts, wiring, whether off the breaker in and out in the cabinet and sub-closing operation, observe whether the abnormal . The meter to zero, according to the wiring diagram to check the secondary wiring is correct. Check interlock whether. 1, the equipment for full phone tracking service. 2, the warranty period since the equipment installation, commissioning is completed and the date of acceptance of counting, addition to wearing parts and operating system software outside the whole year warranty (see details in the sales contract) 3, human reason or improper operation and natural disasters, force majeure factors cause a malfunction, not out of warranty. 4, after the warranty period, parts maintenance costs below the market price received by the Company for life to provide technical support services; Create an installation, routine maintenance, maintenance services file detailed records of equipment use, repair, maintenance situation. 6, the regular telephone visit to solve the specific problems encountered in the operation of the equipment and take preventive measures. 7, providing a range of equipment to use, easy maintenance and technical training. 8, we will be in management, technical full account of the device after-sale service, less a problem for the system, not to provide comprehensive protection. 9, during the warranty period: equipment problems, first resolved by the hotline can not solve, such as by phone, then I plant to send personnel to the scene to solve. 10, response time is as follows: (For my plant is sent to the site maintenance, I plant received a phone call immediately after departure) (1), Dongguan city two hours. (2), 2-8 hours in Guangdong province. (3), outside the province within 24-72 hours. Electric Co., Ltd. of Guangdong purple Miss Yuan: 15217527758 Miss Yuan: 13528580998 Tel :0769 -2,268,880,122,688,802 Fax :0769 -22,688,848 QQ: 474 758 779 QQ: 694 203 949 E-mail: sanli@sanlidq.com Ali Want: gdzgdq dgpdq Web site: www.sanlidq.com Address: Dongcheng District, Dongguan City, Guangdong Province Gap, Industrial Area |
Admin>>>
You are the 6312 visitor
Copyright © GuangDong ICP No. 10089450, Electric Co., Ltd. of Guangdong purple All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6312 visitor
Copyright © GuangDong ICP No. 10089450, Electric Co., Ltd. of Guangdong purple All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility